Marsh Grease Trap Kitchen Fats, Oils and Grease 3850 litres - Suits 1000 Meals

Code:
MARFOG3850

The green clean solution to ensure drains & sewage plants are not blocked. Marsh Grease Trap Features No smell or odour Low carbon footprint No dosing required Ensures drains do not block Aids the performance process of sewage plants Low on-going maintenance Mars...Read More

Create a wishlist

"excellent service from this company"

Scott Flockhart

Description

The green clean solution to ensure drains & sewage plants are not blocked.

Marsh Grease Trap Features

  • No smell or odour
  • Low carbon footprint
  • No dosing required
  • Ensures drains do not block
  • Aids the performance process of sewage plants
  • Low on-going maintenance
  • Marsh fats, oil & grease traps need inspecton for regular cleaning
  • The F.O.G Traps prevent fats oil and grease from entering sewage treatment plants
  • Constructon GRP
  • Inverts 100mm-1000mm
  • High level alarms available including telemetry

From 150-1000 servings/day. The Marsh Polylok Grease Trap stops fats, oil and grease (FOG) from entering the drainage channel each chamber has intergrel baffle plate and Polylok filter fitted.

EN1825 the new European design standard for Grease Separators details the correct sizing method for the calculaton of the nominal size (NS) of grease traps there are four major criteria and calculatons are required.

  • Maximum fow rate of water over a twenty four hour period.
  • Maximum temperature of water.
  • Density of grease/oils to be separated or trapped.
  • Influence of cleaning and rinsing agents used.

For calculaton purpose we assume that parts 2, 3 and 4 all have a denominaton of 3. when multplied together, then a simple calculaton can be used to ascertain the size of unit required. This is the maximum fow rate x 3.

For Example:

If you use 1000 litres per day take 70% of this then divide this by the number of hours the facilites are in use, then divide by 60 to minutes then divide by 60 to seconds. As an example a small cafe serving hot food running 8 hours and using 1000 litres per day of water (70%) metre reading will only generate a fow of 0.03 litres per second, multply this by 1.5 and the nominal size required is only 0.05. It is recommended that a product just above the calculated nominal size is used. The standard also requires that the unit has then to have a minimum volume for sludge (solids, vegetable mater) of 100 tmes the nominal size for all installatons, other than abatoirs and similar establishments which require it to be 200 tmes. So for the above applicaton of 1000 litres of water per day then the trap would have a sludge/solids retenton of around 5 litres. So you would use our base model MAR 1 with or the flter which would give you 30 times this amount.

Dimensions

Height: 2000mm
Diameter: 1700mm
Inlet: 110mm inlet at invert 500mm (below invert 3200 litres)